U.S. manufacturer sourcesSelected products · Reviewed Nov 9, 2026 · Open a record for sources.
LENS RECORD · Biotrue ONEday

Biotrue ONEday

Manufacturer-listed

Bausch + Lomb · Spherical · Daily

Daily disposable spherical lens. One sphere-step boundary is unresolved between the linked manufacturer sources.

AT A GLANCE

Core specifications

Lens design
Spherical
Replacement schedule
Daily
Material
Hydrogel
Material name
nesofilcon A
Base curve
8.6 mm
Diameter
14.2 mm
Water content
78%
Cylinder / axis
Not applicable
Add power / label
Not applicable
Market
United States
Product status
Manufacturer-listed

Oxygen properties

Dk · permeability42
Dk/t · transmissibility42

Dk/t 42 at −3.00 D is reported on the product page. The package insert separately reports Dk 42 × 10⁻¹¹ (cm³ O₂(STP)·cm)/(s·cm²·mmHg), measured at 35°C using the polarographic method. These are independent source values. Dk and Dk/t are distinct properties; neither is calculated from the other.

SOURCE PARAMETER GRID

Find a valid combination

Partial source coverage

Choose one or more parameters. All selected values must occur together in a single lens variant. This checks the documented parameter grid, not current stock.

Verified bands: −6.00 to +6.00 D in 0.25 D steps, and −12.00 to −6.50 D in 0.50 D steps. Do not infer −6.25 D from the product page's ambiguous boundary wording.

Explore the documented parameter grid

61 combinations represented from the source grid. Individual values cannot be freely combined.

View listed combinations (61 total)

Each row is one combination represented from the source grid. “Not applicable” means this design does not use that parameter.

Source-backed parameter combinations for Biotrue ONEday
VariantSphere (D)Cylinder (D)Axis (°)Add power / labelBase curve (mm)Diameter (mm)
Insert-confirmed sphere −6.00 to +6.00 D-6.00Not applicableNot applicableNot applicable8.614.2
Insert-confirmed sphere −6.00 to +6.00 D-5.75Not applicableNot applicableNot applicable8.614.2
Insert-confirmed sphere −6.00 to +6.00 D-5.50Not applicableNot applicableNot applicable8.614.2
Insert-confirmed sphere −6.00 to +6.00 D-5.25Not applicableNot applicableNot applicable8.614.2
Insert-confirmed sphere −6.00 to +6.00 D-5.00Not applicableNot applicableNot applicable8.614.2
Insert-confirmed sphere −6.00 to +6.00 D-4.75Not applicableNot applicableNot applicable8.614.2
Insert-confirmed sphere −6.00 to +6.00 D-4.50Not applicableNot applicableNot applicable8.614.2
Insert-confirmed sphere −6.00 to +6.00 D-4.25Not applicableNot applicableNot applicable8.614.2
Insert-confirmed sphere −6.00 to +6.00 D-4.00Not applicableNot applicableNot applicable8.614.2
Insert-confirmed sphere −6.00 to +6.00 D-3.75Not applicableNot applicableNot applicable8.614.2
Insert-confirmed sphere −6.00 to +6.00 D-3.50Not applicableNot applicableNot applicable8.614.2
Insert-confirmed sphere −6.00 to +6.00 D-3.25Not applicableNot applicableNot applicable8.614.2
Insert-confirmed sphere −6.00 to +6.00 D-3.00Not applicableNot applicableNot applicable8.614.2
Insert-confirmed sphere −6.00 to +6.00 D-2.75Not applicableNot applicableNot applicable8.614.2
Insert-confirmed sphere −6.00 to +6.00 D-2.50Not applicableNot applicableNot applicable8.614.2
Insert-confirmed sphere −6.00 to +6.00 D-2.25Not applicableNot applicableNot applicable8.614.2
Insert-confirmed sphere −6.00 to +6.00 D-2.00Not applicableNot applicableNot applicable8.614.2
Insert-confirmed sphere −6.00 to +6.00 D-1.75Not applicableNot applicableNot applicable8.614.2
Insert-confirmed sphere −6.00 to +6.00 D-1.50Not applicableNot applicableNot applicable8.614.2
Insert-confirmed sphere −6.00 to +6.00 D-1.25Not applicableNot applicableNot applicable8.614.2
Insert-confirmed sphere −6.00 to +6.00 D-1.00Not applicableNot applicableNot applicable8.614.2
Insert-confirmed sphere −6.00 to +6.00 D-0.75Not applicableNot applicableNot applicable8.614.2
Insert-confirmed sphere −6.00 to +6.00 D-0.50Not applicableNot applicableNot applicable8.614.2
Insert-confirmed sphere −6.00 to +6.00 D-0.25Not applicableNot applicableNot applicable8.614.2
Insert-confirmed sphere −6.00 to +6.00 D0.00Not applicableNot applicableNot applicable8.614.2
Insert-confirmed sphere −6.00 to +6.00 D+0.25Not applicableNot applicableNot applicable8.614.2
Insert-confirmed sphere −6.00 to +6.00 D+0.50Not applicableNot applicableNot applicable8.614.2
Insert-confirmed sphere −6.00 to +6.00 D+0.75Not applicableNot applicableNot applicable8.614.2
Insert-confirmed sphere −6.00 to +6.00 D+1.00Not applicableNot applicableNot applicable8.614.2
Insert-confirmed sphere −6.00 to +6.00 D+1.25Not applicableNot applicableNot applicable8.614.2

Showing the first 30 of 61 listed combinations. Select more parameters to narrow the list.

DATA & SOURCES

Official manufacturer sources

U.S. source review

The product page's step-boundary wording differs from the linked package insert (Rev. 2019-11). The explicit insert bands are encoded; −6.25 D remains unconfirmed rather than inferred. Coverage is marked incomplete pending manufacturer clarification.

Verified bands: −6.00 to +6.00 D in 0.25 D steps, and −12.00 to −6.50 D in 0.50 D steps. Do not infer −6.25 D from the product page's ambiguous boundary wording.

Biotrue ONEday — U.S. parameters

Accessed

Location: Contact lens parameters section; sphere-step wording compared with linked package insert

Supports: U.S. market; Replacement schedule; Material type; Water content; Dk/t · transmissibility; Base curve; Diameter; Parameter grid

Biotrue ONEday package insert and fitting guide

Accessed · Revision: 2019-11

Location: PDF page 1; printed sections Description (p.2) and Lens Parameters Available (p.5)

Supports: Dk · permeability; Sphere increments; Toric -2.75 cylinder sphere increments; Add categories

Parameter coverage
Incomplete — unlisted combinations remain unknown
Listed parameters
61 listed combinations · partial set
Search aliases
Biotrue 1 day, Biotrue sphere

Parameter matches describe the cited U.S. source grid. They do not confirm stock or establish clinical interchangeability.