U.S. manufacturer sourcesSelected products · Reviewed Nov 9, 2026 · Open a record for sources.
LENS RECORD · OASYS 1-Day

ACUVUE OASYS 1-Day with HydraLuxe

Manufacturer-listed

ACUVUE · Spherical · Daily

Daily disposable spherical senofilcon A lens with two published base curves.

AT A GLANCE

Core specifications

Lens design
Spherical
Replacement schedule
Daily
Material
Silicone hydrogel
Material name
senofilcon A
Base curve
8.5 / 9.0 mm
Diameter
14.3 mm
Water content
38%
Cylinder / axis
Not applicable
Add power / label
Not applicable
Market
United States
Product status
Manufacturer-listed

Oxygen properties

Dk · permeabilityUnknown
Dk/t · transmissibility121

Dk/t is reported in ×10⁻⁹ (cm/s)(mL O₂/mL·mmHg), at the center of a −3.00 D lens at 35°C using a polarographic method with boundary and edge corrections. Dk is not separately supplied in the cited specification table. Dk and Dk/t are distinct properties; neither is calculated from the other.

SOURCE PARAMETER GRID

Find a valid combination

Published grid transcribed

Choose one or more parameters. All selected values must occur together in a single lens variant. This checks the documented parameter grid, not current stock.

The U.S. sphere table excludes plano and ±0.25 D. Inner bands use 0.25 D steps from ±0.50 to ±6.00; outer bands use 0.50 D steps to −12.00 and +8.00.

Explore the documented parameter grid

124 combinations represented from the source grid. Individual values cannot be freely combined.

View listed combinations (124 total)

Each row is one combination represented from the source grid. “Not applicable” means this design does not use that parameter.

Source-backed parameter combinations for ACUVUE OASYS 1-Day with HydraLuxe
VariantSphere (D)Cylinder (D)Axis (°)Add power / labelBase curve (mm)Diameter (mm)
8.5 mm base curve · published sphere bands-12.00Not applicableNot applicableNot applicable8.514.3
8.5 mm base curve · published sphere bands-11.50Not applicableNot applicableNot applicable8.514.3
8.5 mm base curve · published sphere bands-11.00Not applicableNot applicableNot applicable8.514.3
8.5 mm base curve · published sphere bands-10.50Not applicableNot applicableNot applicable8.514.3
8.5 mm base curve · published sphere bands-10.00Not applicableNot applicableNot applicable8.514.3
8.5 mm base curve · published sphere bands-9.50Not applicableNot applicableNot applicable8.514.3
8.5 mm base curve · published sphere bands-9.00Not applicableNot applicableNot applicable8.514.3
8.5 mm base curve · published sphere bands-8.50Not applicableNot applicableNot applicable8.514.3
8.5 mm base curve · published sphere bands-8.00Not applicableNot applicableNot applicable8.514.3
8.5 mm base curve · published sphere bands-7.50Not applicableNot applicableNot applicable8.514.3
8.5 mm base curve · published sphere bands-7.00Not applicableNot applicableNot applicable8.514.3
8.5 mm base curve · published sphere bands-6.50Not applicableNot applicableNot applicable8.514.3
8.5 mm base curve · published sphere bands-6.00Not applicableNot applicableNot applicable8.514.3
8.5 mm base curve · published sphere bands-5.75Not applicableNot applicableNot applicable8.514.3
8.5 mm base curve · published sphere bands-5.50Not applicableNot applicableNot applicable8.514.3
8.5 mm base curve · published sphere bands-5.25Not applicableNot applicableNot applicable8.514.3
8.5 mm base curve · published sphere bands-5.00Not applicableNot applicableNot applicable8.514.3
8.5 mm base curve · published sphere bands-4.75Not applicableNot applicableNot applicable8.514.3
8.5 mm base curve · published sphere bands-4.50Not applicableNot applicableNot applicable8.514.3
8.5 mm base curve · published sphere bands-4.25Not applicableNot applicableNot applicable8.514.3
8.5 mm base curve · published sphere bands-4.00Not applicableNot applicableNot applicable8.514.3
8.5 mm base curve · published sphere bands-3.75Not applicableNot applicableNot applicable8.514.3
8.5 mm base curve · published sphere bands-3.50Not applicableNot applicableNot applicable8.514.3
8.5 mm base curve · published sphere bands-3.25Not applicableNot applicableNot applicable8.514.3
8.5 mm base curve · published sphere bands-3.00Not applicableNot applicableNot applicable8.514.3
8.5 mm base curve · published sphere bands-2.75Not applicableNot applicableNot applicable8.514.3
8.5 mm base curve · published sphere bands-2.50Not applicableNot applicableNot applicable8.514.3
8.5 mm base curve · published sphere bands-2.25Not applicableNot applicableNot applicable8.514.3
8.5 mm base curve · published sphere bands-2.00Not applicableNot applicableNot applicable8.514.3
8.5 mm base curve · published sphere bands-1.75Not applicableNot applicableNot applicable8.514.3

Showing the first 30 of 124 listed combinations. Select more parameters to narrow the list.

DATA & SOURCES

Official manufacturer sources

U.S. source review

Reviewed November 9, 2026 against U.S. Johnson & Johnson Vision professional product specifications and the current v17 guide. Completeness describes the published parameter grid, not stock or the entire ACUVUE portfolio. Package quantities are not modeled.

The U.S. sphere table excludes plano and ±0.25 D. Inner bands use 0.25 D steps from ±0.50 to ±6.00; outer bands use 0.50 D steps to −12.00 and +8.00.

J&J Vision U.S. OASYS 1-Day with HydraLuxe specifications

Accessed

Location: Lens specifications table and oxygen-transmissibility footnote.

Supports: Identity; Replacement schedule; Material type; Sphere power; Base curve; Diameter; Water content; Dk/t · transmissibility

ACUVUE U.S. Product Specification Sheet

Accessed · Revision: PP2020ACLP4800 v17 · ©2026

Location: Page 1: product column and parameter grid; page 4: measurement footnotes. Linked from the U.S. Lens Parameters page.

Supports: Identity; Replacement schedule; Material type; Sphere power; Base curve; Diameter; Water content; Dk/t · transmissibility

Parameter coverage
Complete within the cited parameter grid
Listed parameters
124 listed combinations
Search aliases
Oasys daily spherical, Johnson and Johnson

Parameter matches describe the cited U.S. source grid. They do not confirm stock or establish clinical interchangeability.