PRECISION1
Manufacturer-listedAlcon · Spherical · Daily
Daily disposable spherical lens in verofilcon A with a surface water layer.
Core specifications
- Lens design
- Spherical
- Replacement schedule
- Daily
- Material
- Silicone hydrogel
- Material name
- verofilcon A
- Base curve
- 8.3 mm
- Diameter
- 14.2 mm
- Water content
- 51%
- Cylinder / axis
- Not applicable
- Add power / label
- Not applicable
- Market
- United States
- Product status
- Manufacturer-listed
Oxygen properties
Manufacturer-reported Dk/t 100 at −3.00 D. The cited specification table does not state units or a measurement method. Dk is not separately given in that table and is not derived from Dk/t. Water content shown is core water content, not surface water content. Dk and Dk/t are distinct properties; neither is calculated from the other.
Find a valid combination
Choose one or more parameters. All selected values must occur together in a single lens variant. This checks the documented parameter grid, not current stock.
The published spherical bands start at ±0.50 D; plano and ±0.25 are not listed. Steps are 0.25 D through ±6.00, then 0.50 D to −12.00 and +8.00.
62 combinations represented from the source grid. Individual values cannot be freely combined.
View listed combinations (62 total)
Each row is one combination represented from the source grid. “Not applicable” means this design does not use that parameter.
| Variant | Sphere (D) | Cylinder (D) | Axis (°) | Add power / label | Base curve (mm) | Diameter (mm) |
|---|---|---|---|---|---|---|
| U.S. sphere table: +0.50 to +6.00 / 0.25 D | +0.50 | Not applicable | Not applicable | Not applicable | 8.3 | 14.2 |
| U.S. sphere table: +0.50 to +6.00 / 0.25 D | +0.75 | Not applicable | Not applicable | Not applicable | 8.3 | 14.2 |
| U.S. sphere table: +0.50 to +6.00 / 0.25 D | +1.00 | Not applicable | Not applicable | Not applicable | 8.3 | 14.2 |
| U.S. sphere table: +0.50 to +6.00 / 0.25 D | +1.25 | Not applicable | Not applicable | Not applicable | 8.3 | 14.2 |
| U.S. sphere table: +0.50 to +6.00 / 0.25 D | +1.50 | Not applicable | Not applicable | Not applicable | 8.3 | 14.2 |
| U.S. sphere table: +0.50 to +6.00 / 0.25 D | +1.75 | Not applicable | Not applicable | Not applicable | 8.3 | 14.2 |
| U.S. sphere table: +0.50 to +6.00 / 0.25 D | +2.00 | Not applicable | Not applicable | Not applicable | 8.3 | 14.2 |
| U.S. sphere table: +0.50 to +6.00 / 0.25 D | +2.25 | Not applicable | Not applicable | Not applicable | 8.3 | 14.2 |
| U.S. sphere table: +0.50 to +6.00 / 0.25 D | +2.50 | Not applicable | Not applicable | Not applicable | 8.3 | 14.2 |
| U.S. sphere table: +0.50 to +6.00 / 0.25 D | +2.75 | Not applicable | Not applicable | Not applicable | 8.3 | 14.2 |
| U.S. sphere table: +0.50 to +6.00 / 0.25 D | +3.00 | Not applicable | Not applicable | Not applicable | 8.3 | 14.2 |
| U.S. sphere table: +0.50 to +6.00 / 0.25 D | +3.25 | Not applicable | Not applicable | Not applicable | 8.3 | 14.2 |
| U.S. sphere table: +0.50 to +6.00 / 0.25 D | +3.50 | Not applicable | Not applicable | Not applicable | 8.3 | 14.2 |
| U.S. sphere table: +0.50 to +6.00 / 0.25 D | +3.75 | Not applicable | Not applicable | Not applicable | 8.3 | 14.2 |
| U.S. sphere table: +0.50 to +6.00 / 0.25 D | +4.00 | Not applicable | Not applicable | Not applicable | 8.3 | 14.2 |
| U.S. sphere table: +0.50 to +6.00 / 0.25 D | +4.25 | Not applicable | Not applicable | Not applicable | 8.3 | 14.2 |
| U.S. sphere table: +0.50 to +6.00 / 0.25 D | +4.50 | Not applicable | Not applicable | Not applicable | 8.3 | 14.2 |
| U.S. sphere table: +0.50 to +6.00 / 0.25 D | +4.75 | Not applicable | Not applicable | Not applicable | 8.3 | 14.2 |
| U.S. sphere table: +0.50 to +6.00 / 0.25 D | +5.00 | Not applicable | Not applicable | Not applicable | 8.3 | 14.2 |
| U.S. sphere table: +0.50 to +6.00 / 0.25 D | +5.25 | Not applicable | Not applicable | Not applicable | 8.3 | 14.2 |
| U.S. sphere table: +0.50 to +6.00 / 0.25 D | +5.50 | Not applicable | Not applicable | Not applicable | 8.3 | 14.2 |
| U.S. sphere table: +0.50 to +6.00 / 0.25 D | +5.75 | Not applicable | Not applicable | Not applicable | 8.3 | 14.2 |
| U.S. sphere table: +0.50 to +6.00 / 0.25 D | +6.00 | Not applicable | Not applicable | Not applicable | 8.3 | 14.2 |
| U.S. sphere table: +6.50 to +8.00 / 0.50 D | +6.50 | Not applicable | Not applicable | Not applicable | 8.3 | 14.2 |
| U.S. sphere table: +6.50 to +8.00 / 0.50 D | +7.00 | Not applicable | Not applicable | Not applicable | 8.3 | 14.2 |
| U.S. sphere table: +6.50 to +8.00 / 0.50 D | +7.50 | Not applicable | Not applicable | Not applicable | 8.3 | 14.2 |
| U.S. sphere table: +6.50 to +8.00 / 0.50 D | +8.00 | Not applicable | Not applicable | Not applicable | 8.3 | 14.2 |
| U.S. sphere table: −0.50 to −6.00 / 0.25 D | -6.00 | Not applicable | Not applicable | Not applicable | 8.3 | 14.2 |
| U.S. sphere table: −0.50 to −6.00 / 0.25 D | -5.75 | Not applicable | Not applicable | Not applicable | 8.3 | 14.2 |
| U.S. sphere table: −0.50 to −6.00 / 0.25 D | -5.50 | Not applicable | Not applicable | Not applicable | 8.3 | 14.2 |
Showing the first 30 of 62 listed combinations. Select more parameters to narrow the list.
Official manufacturer sources
Transcribed from Alcon's United States professional specifications, reviewed November 9, 2026. Complete refers to the published product grid, not the full Alcon portfolio or real-time stock. Water content is the core value.
The published spherical bands start at ±0.50 D; plano and ±0.25 are not listed. Steps are 0.25 D through ±6.00, then 0.50 D to −12.00 and +8.00.
Accessed · Revision: US-PR1-2200002
Location: PRECISION1 parameters: four sphere bands, geometry, core water and Dk/t.
Supports: Identity; Replacement schedule; Material name; Sphere power; Base curve; Diameter; Water content; Dk/t · transmissibility
Accessed
Location: Page 2: verofilcon A silicone hydrogel core and 51% core water content.
Supports: Material type
- Parameter coverage
- Complete within the cited parameter grid
- Listed parameters
- 62 listed combinations
- Search aliases
- Precision 1
Parameter matches describe the cited U.S. source grid. They do not confirm stock or establish clinical interchangeability.